Report item
Item specifics
  • Item Type: Toothbrush Sanitizer
  • Model Number: MAX-10A
Product Description
1.Digital Display; 2.ClassB Autoclave;
3.Three times pulse vacuum dring functon; 4.vacuum ability up to -0.82bar;  5.Residual humidity is <0.2%;
6.Spiral pipe steam generator 7.Automatic door device
8.Pressure power devices:If the pressure in the sterilization chamber is more than 5Kpa,the sterilizer will cut off auomatically,the door can not be opened
9.Printer and USB inerface can be provided if required
10.Water tank alarmLack water in the storage tank,waste water tank is full of water
11.Fault detection alarm system
12.The fatest sterilization procedures only need 15 minutes,for classB the fatest application need 35 minutes

 Generally, the lock doesn’t need to be adjusted. But if the seal is ok and replace the sealing ring failure, you can adjust the lock with wrench.

Open the door.

Put the screwdriver into the plastic casing (Picture 7-1), insert the mouth of the screwdriver into the adjusting nut (Picture 7-2). Rotate clockwise, proper strength is ok.

 

   

           Picture 7-1                           Picture 7-2

Maintain and Preserve

 

Time Schedule of the Autoclave Maintain

Time

Content

Order

 

Every week

Use wet cloth to clean the sealing face

1

Clean the copper filter

2

Use medicinal alcohol to clean tube inner surface.

3

Every month

Use cloth with toothpaste to clean the appearance of the autoclave

1

Clean the stainless steel instrument stray

2

Every three ~ six month

Replace the water filter

1

Clean the water box with medicinal disinfecting water

2

Every year

Replace the door lock seal

1

Replace the copper filter

2

Replace the fuse

3

 

     

 

DO NOT PULL AUTOCLAVE DURING TRANSPORT

 

Fault code

   

   When there is something wrong during working, the autoclave will alarm, release the pressure and stop heating. At the same time, the autoclave will show the fault code.

 

NO.

Fault code

Alarm

Content

Dealing

0

E0

Toot

Uncorrected

Correct the Program

1

E1

Toot

The temperature sensor error

Check the temperature sensor

2

E2

Toot

Overpressure or pressure sensor failure

Check the pressure sensor

3

E3

Toot

Overtemperature

Check the installation of temperature sensor

4

E4

Toot

Heating failure

Check if air leakage

5

E5

Toot

Pressure releasing failure

Check the Exhaust solenoid valve

6

E6

Toot

The door switch off at work

Check if the door handle is tight

7

E7

Toot

Correct failure

Check and Correct the control panel

8

E8

Toot

Correct failure

Check the suction culvert and air leakage

9

E9

Toot

Keep pressure failure

Check if air leakage

 

If the problem still can not be solved according to the above, please contact the local dealers.

 

 

 

Appendix

 

No.

Display

State

State Explanation

1

Ld

Preheating

Preparation for sterilizing

2

He

Heating

The autoclave starts to heat and boost

3

-p

Vacuumize

Forevacuum or thirdly Vacuumizing

4

Work Time

Sterilizing

Display working time

5

PL

Dry

Dry the instrument in the autoclave

6

Ed

End

End of the program, can open the door

7

Fault Code

Fault

Display fault code

 

 

 

Packaging Details
  • Unit Type: piece
  • Package Weight: 48.0kg (105.82lb.)
  • Package Size: 72cm x 53cm x 560cm (28.35in x 20.87in x 220.47in)
Shipping
Calculate your shipping cost by country/region and quantity.
Quantity: Ship to:
Packaging Details
  • Unit Type: piece
  • Package Weight: 48.0kg (105.82lb.)
  • Package Size: 72cm x 53cm x 560cm (28.35in x 20.87in x 220.47in)
Payment
We support the following payment methods. All payments made on AliExpress are processed by Alipay.